2D ENGINE NACELLE
OBSTRUCTION FIRE SIMULATOR


This is a low speed blower driven wind tunnel with controlled turbulence intensity levels and fitted for flammable fluid fuel pool.
The test section is 9” high and 72” wide and 8’ streamwise length enabling a highly two-dimensional boundary layer flow.
The test section is re-enforced to prevent sagging in the presence of a long burning pool fire.
There are also several optical ports that are 6” x 6” in dimension fitted with a sapphire windows.


A 10” x 12” constant level flammable fluid pool located within the test section is also available.